Christie 03-900471-01P projector lamp, UHP 200W, reflector 80X80L, compatible with L6, RD-RNR L6, VIVID Blue and other 3 Christie projectors. Zorsika equivalent model 03-900471-01P.

Christie 03-900471-01P Projector Lamp for L6 RD-RNR L6 VIVID Blue OEM Replacement

Christie 03-900471-01P Projector Lamp for L6 RD-RNR L6 VIVID Blue OEM Replacement

Projector brightness dropping, or an alarm prompting a lamp replacement right after power-on? Most of the time it just means the lamp needs replacing—but finding the right model can be even more of a headache. This article explains exactly which Christie projectors the 03-900471-01P fits and what to watch out for.

Christie 03-900471-01P Projector Lamp

Christie 03-900471-01P Compatible Projector Models (3 in total)

The following are verified compatible Christie projector models for the 03-900471-01P, separated by commas:

L6, RD-RNR L6, VIVID Blue

Note: Projectors of the same generation often share the same lamp module. For models not listed, contact Zorsika technical support for confirmation.

Specifications at a Glance

Original Lamp Module Model03-900471-01P
Zorsika Equivalent Model03-900471-01P
Compatible BrandChristie
Lamp Module SpecUHP200W 1.3 P22.5
Lamp TypeUHP
Rated Power200W
Arc Gap1.3mm
Reflector Size80X80L
Projection TechnologyLCD
Number of Compatible Models3

The above specifications come from the Zorsika product database. Contact sales for the complete technical datasheet.

Frequently Asked Questions

Q: What should I do if the projector says the lamp is not recognized after replacement?

A: First check whether the lamp timer has been reset. The vast majority of such prompts are caused by the timer not being cleared. If the error persists after resetting, contact Zorsika technical support—we provide the reset procedure and troubleshooting guidance for the corresponding model.

Q: How do I choose between original packaged, original bare, and aftermarket?

A: If you want stable brightness and long-term reliability, the Zorsika PRO series lamp is the first choice—it matches original specifications item by item, is individually powered-on and tested before leaving the factory, delivers performance on par with the original while being more worry-free overall, and comes with a 180-day warranty. For routine business, education, and conference room use, the PRO series is also the more worry-free option overall. Other replacement lamps cost less, but arc tube sourcing and quality control vary widely, with higher risk of brightness degradation and shortened lifespan—they are only recommended for temporary backup units.

Q: Why choose Zorsika PRO instead of the original?

A: The core logic of the Zorsika PRO series lamp is "original specifications, in-house quality control": power, arc gap, and reflector size all match the original item by item, but with an extra individual power-on test before shipping and a 180-day warranty. Compared with the original, it is more worry-free overall; compared with other replacement options, quality control is more consistent.

Q: Is there an installation guide for the 03-900471-01P?

A: Yes. The lamp door location and removal/installation steps for these Christie models are basically the same. Contact Zorsika sales for illustrated or video guides for the corresponding model.

Q: How long is the lamp warranty?

A: Zorsika PRO series projector lamps come with a 180-day warranty. Under normal use and non-human-caused damage (such as lamp explosion or abnormal early brightness degradation), after-sales service applies; brightness degradation within the standard range is normal wear and is not covered by the warranty.

What the Zorsika PRO Series Offers You

For high-volume standard lamp modules like the 03-900471-01P, the Zorsika PRO series provides a replacement solution with the same specifications as the original—power, arc gap, and reflector size all match the original item by item, each unit is individually powered-on and tested before shipping, and it is ready to install without structural modification.

  • Specification matching: Power, arc gap, and reflector size matched item by item to original parameters
  • Individual testing: Each unit powered-on and tested before shipping, ensuring brightness and stability
  • Warranty commitment: 180-day lamp warranty; normal use with non-human-caused damage is covered by after-sales service
  • Stable supply: Supports bulk purchasing and project supply

In one sentence: if you want original-level quality with a more worry-free overall experience, the Zorsika PRO series projector lamp is made for exactly this scenario.

Note: Performance such as brightness and lifespan is significantly affected by projector condition, usage environment, and cooling conditions. Zorsika does not make uniform numerical promises. Before bulk purchasing, we recommend obtaining 1-2 samples for power-on testing.

Routine Maintenance to Make Your Lamp Last Longer

  • Clean dust promptly: Dust buildup on the air intake and air filter directly raises the lamp's operating temperature. In dusty environments, clean every 1-2 months; in ordinary office environments, every 3-6 months.
  • Use eco mode: Use eco mode whenever brightness is sufficient to reduce the lamp's thermal load.
  • Avoid frequent on/off cycling: Thermal cycling is one of the main causes of lamp wear. If not in use for a short time, use the shutter function instead of repeatedly cutting power.
  • Shut down properly: After powering off, wait for the fan to stop before cutting power. Cutting power while hot causes the lamp to cool abruptly, a common cause of lamp explosion.
  • Reset after replacement: After installing a new lamp, be sure to reset the lamp timer in the menu; otherwise the projector will keep alarming based on the old timer.

Related Links

Purchasing Inquiries

For solution consultation, bulk proposals, or the complete compatible model list for the Christie 03-900471-01P, contact us via:

  • Website: www.zorsika.com
  • Phone: 0086-20-38551187
  • Email: sales@zorsika.com
  • Business Hours: Monday to Friday, 9:00-18:00

The lamp module models, specifications, and compatible model data in this article all come from the Zorsika product database. Data is continuously updated; please confirm with an actual quotation.