At a glance
- Lamp Specifications
- Christie 003-000884-01 Compatible Projector Models (4 Models Total)
- Before Placing an Order, Check These Three Things
- Why Choose Zorsika PRO Series
- Regular Maintenance to Extend Lamp Life
- Frequently Asked Questions
- Q: My projector is not on the list of 4 models above. Can I use 003-000884-01?
- Q: How do I choose between original packaging, bare lamp, and alternative?
- Q: Why choose Zorsika PRO over OEM?
- Q: What to do if the projector shows "lamp not recognized" after replacement?
- Q: Is there an installation tutorial for 003-000884-01?
- Q: How long is the lamp warranty period?
- Related Resources
- Procurement Inquiry
Christie 003-000884-01 projector lamp, UHP 300W/250W dual mode, reflector 56X56D, socket E21.8, compatible with HD405, DS+655, DS+650, DS+65 four Christie projectors. Zorsika corresponding model Z-000884.


Lamp Specifications
| Original Lamp Module Model | 003-000884-01 |
| Zorsika Corresponding Model | Z-000884 |
| Compatible Brand | Christie |
| Lamp Module Spec | UHP300/250W 1.3 E21.8 |
| Lamp Type | UHP |
| Rated Power | 300W (standard mode) / 250W (eco mode) |
| Arc Gap | 1.3mm |
| Socket Spec | E21.8 |
| Reflector Size | 56X56D |
| Projection Technology | DLP |
| Number of Compatible Models | 4 models |
All specifications above are sourced from the Zorsika product database. For complete technical datasheets, please contact your sales representative.
Christie 003-000884-01 Compatible Projector Models (4 Models Total)
Below are the verified compatible projector models for 003-000884-01 in Christie projectors, with model numbers separated by commas:
HD405, DS+655, DS+650, DS+65
Note: Projectors of the same generation often share the same lamp module. For models not listed, please contact Zorsika technical support for confirmation.
Before Placing an Order, Check These Three Things
- Verify the nameplate model number: Open the projector lamp door and check that the model on the lamp module label matches 003-000884-01 exactly. Some Christie models may have suffix variations like -V or +, but the lamp module is usually interchangeable. When uncertain, take a photo of the nameplate and send it to Zorsika technical support for confirmation.
- Confirm the lamp configuration: The same model is available in four configurations: original packaged, original bare, replacement, and used. The differences between these are significant. Original bare refers to an OEM lamp core with an aftermarket lamp housing, which typically offers the best overall value. When purchasing, be sure to clearly specify which configuration you need on your order to avoid disputes upon receipt.
- Verify physical specifications: The reflector size of 56X56D, socket type E21.8, and arc gap must match the original lamp. Any mismatch may result in the lamp failing to fit or illuminate properly.
Why Choose Zorsika PRO Series
The Zorsika PRO series provides OEM-spec equivalent lamp modules for 003-000884-01, with all key parameters matched to original specs item by item, supporting project supply and bulk procurement with more controllable lead times.
- Specification Match: Power, arc gap, and reflector size are matched to OEM specs item by item
- Individual Testing: Each lamp is tested before shipment, ensuring brightness and stability
- Warranty: 180-day warranty on lamps, covering normal use non-human damage with after-sales service
- Stable Supply: Supports bulk procurement and project supply
Bottom line: If you want OEM quality with greater convenience, the Zorsika PRO series projector lamp is designed for exactly this scenario.
Note: Brightness, lifespan, and other performance metrics vary significantly with machine condition, usage environment, and thermal management. Zorsika does not make unified numerical commitments. We recommend ordering 1-2 sample units for testing before bulk procurement.
Regular Maintenance to Extend Lamp Life
- Keep Dust-Free: Dust buildup on the air intake and air filter directly increases lamp operating temperature. Clean every 1-2 months in dusty environments, or every 3-6 months in typical office settings.
- Use Eco Mode: This lamp supports dual power modes (300W / 250W). Switching to eco mode in normal presentation scenarios significantly reduces lamp thermal load.
- Avoid Frequent Switching: Thermal cycling is a major cause of lamp degradation. If not using for a short period, use the blackout function instead of repeatedly turning the power on and off.
- Proper Shutdown: Always wait for the fan to stop before disconnecting power. Shutting down while hot causes the lamp to cool abruptly, a common cause of lamp failure.
- Reset After Replacement: After installing a new lamp, be sure to reset the lamp timer in the menu; otherwise the machine will continue to alert based on the old timer.
Frequently Asked Questions
Q: My projector is not on the list of 4 models above. Can I use 003-000884-01?
A: The list shows verified models, not a complete list. Christie products from the same generation often share lamp modules. Take photos of your machine's serial plate and original lamp label and send them to Zorsika technical support for compatibility confirmation.
Q: How do I choose between original packaging, bare lamp, and alternative?
A: For optimal brightness stability and long-term reliability, the Zorsika PRO series lamp is the top choice—with specs matched to OEM one by one, 100% individual testing before shipment, performance on par with OEM, more convenient overall, and 180-day warranty; for regular business, education, and conference use, the PRO series is also more convenient overall. Other alternative lamps have lower costs, but lamp core sources and quality control vary significantly, with higher risks of brightness decay and shortened lifespan—only recommended for temporary backup use.
Q: Why choose Zorsika PRO over OEM?
A: The core logic of the Zorsika PRO series lamp is "OEM specs, self-controlled quality": power, arc gap, and reflector size are matched to OEM specs item by item, but with an additional 100% individual testing before shipment and 180-day warranty. Compared to OEM, it's more convenient overall; compared to other alternatives, quality control is more stable.
Q: What to do if the projector shows "lamp not recognized" after replacement?
A: First confirm whether you reset the lamp timer—most alerts are caused by an uncleared timer. If the error persists after reset, contact Zorsika technical support. We provide reset methods and troubleshooting guides for your specific projector model.
Q: Is there an installation tutorial for 003-000884-01?
A: Yes. The lamp door position and disassembly steps are essentially consistent across these Christie models. Contact Zorsika sales to get illustrated or video tutorials for your specific model.
Q: How long is the lamp warranty period?
A: Zorsika PRO series projector lamps come with 180-day warranty. Normal use and non-human damage (such as lamp failure, abnormal early brightness decay) qualify for after-sales service; brightness decay within standard range is considered normal wear and tear and is not covered by warranty.
Related Resources
- Zorsika Technical Support Center
- Projector Brands & Compatible Models
- Projector Lamp / Lens / Air Filter Product Library
Procurement Inquiry
For inquiries about Christie 003-000884-01 solutions, bulk pricing, or a complete model compatibility list, contact us through:
- Website: www.zorsika.com
- Phone: 0086-20-38551187
- Email: sales@zorsika.com
- Business Hours: Monday to Friday, 9:00-18:00
The lamp module models, specifications, and compatible projector models in this article are sourced from the Zorsika product database. Data is continuously updated and subject to confirmation upon actual inquiry.