At a glance
- Lamp Module Specifications
- Christie 003-005160-01 Compatible Projector Models (3 models total)
- What Zorsika PRO Series Offers
- Frequently Asked Questions
- Q: Why choose Zorsika PRO over OEM or low-cost third-party lamps?
- Q: How do I choose between complete module, bare lamp, or generic replacement?
- Q: The machine displays a lamp not recognized message after lamp replacement. What should I do?
- Q: My projector model is not on the list of 3 models above. Can I use 003-005160-01?
- Q: Is there an installation guide for 003-005160-01?
- Three Things to Check Before Purchasing
- Important Notes After Replacing the Lamp
- Related Search Links
- Purchase Inquiry
Christie 003-005160-01 projector lamp, compatible with DWX851-Q, DWU851-Q, DHD851-Q and 3 other Christie projector models. Zorsika corresponding model Z-005160.


Lamp Module Specifications
| Original Lamp Module Model | 003-005160-01 |
| Zorsika Corresponding Model | Z-005160 |
| Compatible Brand | Christie(Christie) |
| Lamp Module Specs | P-VIP370 CE75H |
| Projection Technology | DLP |
| Number of Compatible Models | 3 models |
The above parameters are sourced from the Zorsika product database. For complete technical specifications, please contact sales to request them.
Christie 003-005160-01 Compatible Projector Models (3 models total)
Below are the verified compatible projector models for 003-005160-01 in Christie projectors, model numbers separated by commas:
DWX851-Q, DWU851-Q, DHD851-Q
What Zorsika PRO Series Offers
The Zorsika PRO series provides OEM-spec replacement lamp modules for 003-005160-01, with every key parameter matched against the original manufacturer. Project supply and bulk orders are supported with more reliable delivery schedules.
- Spec Matching: Power, arc gap, and reflector size are matched item by item to original manufacturer specifications
- Individual Testing: Each lamp undergoes individual light-on testing before shipment, ensuring reliable brightness and stability
- Warranty Commitment: 180-day warranty on projector lamps; normal use with non-human damage is covered under after-sales service
- Stable Supply: Supports bulk orders and project procurement
Bottom line: If you want OEM-quality performance with more peace of mind overall, the Zorsika PRO series projector lamp is designed exactly for this scenario.
Note: Brightness, lifespan, and other performance metrics are heavily influenced by machine condition, usage environment, and thermal management. Zorsika does not make uniform numerical commitments. We recommend ordering 1-2 sample units for light-on testing before bulk procurement.
Frequently Asked Questions
Q: Why choose Zorsika PRO over OEM or low-cost third-party lamps?
A: The core logic behind Zorsika PRO series lamps is "OEM specs, self-controlled quality": power, arc gap, and reflector size are matched item by item to the original manufacturer, but with an additional individual light-on test before shipment and a 180-day warranty. Compared to OEM, it offers more peace of mind overall; compared to low-cost third-party lamps, the quality control is more consistent.
Q: How do I choose between complete module, bare lamp, or generic replacement?
A: If you prioritize brightness stability and long-term reliability, the Zorsika PRO series lamp is the top choice—matched item by item to OEM specifications, individually tested before shipment, OEM-level performance with more peace of mind overall, and backed by a 180-day warranty; for regular business, education, and meeting room use, PRO series also offers more peace of mind overall. Bare lamps and generic replacements have lower costs, but lamp core sourcing and quality control vary significantly, with higher risks of brightness degradation and shortened lifespan. They are only recommended for temporary backup units.
Q: The machine displays a lamp not recognized message after lamp replacement. What should I do?
A: First confirm whether the lamp timer was reset—most error messages are caused by uncleared timer counters. If the error persists after resetting, contact Zorsika technical support; we provide reset methods and troubleshooting guidance for the corresponding projector models.
Q: My projector model is not on the list of 3 models above. Can I use 003-005160-01?
A: The list represents verified models and does not cover all possibilities. Christie products from the same generation often share lamp modules. Take photos of the machine's nameplate and original lamp label and send them to Zorsika technical support—they can help confirm whether the lamp is compatible.
Q: Is there an installation guide for 003-005160-01?
A: Yes. The lamp door positions and disassembly/reassembly steps are essentially consistent across Christie's model range. Contact Zorsika sales to obtain illustrated or video tutorials for your specific projector model.
Three Things to Check Before Purchasing
- Verify the nameplate model: Open the projector lamp door; the model on the lamp module label must exactly match 003-005160-01. Some Christie models may have suffix variations like -V or +, but lamp modules are usually interchangeable. If unsure, take a photo of the nameplate and send it to Zorsika technical support for confirmation.
- Confirm lamp configuration: The same model comes in four types: OEM boxed, OEM bare, compatible, and used. These vary significantly. OEM bare means original lamp core with third-party housing, offering the best overall value. Specify clearly on your order which type you need to avoid disputes after delivery.
- Check physical specifications: Arc gap and other measurements must match the original lamp; any discrepancy may result in the lamp not fitting or failing to ignite.
Important Notes After Replacing the Lamp
- Clean dust regularly: Dust buildup on the air intake and filter directly raises lamp operating temperature. In dusty environments, clean every 1-2 months; in normal office settings, clean every 3-6 months.
- Use eco mode wisely: Prioritize eco mode when brightness is sufficient to reduce lamp thermal load.
- Avoid frequent switching: Thermal cycling is a major cause of lamp wear. If not using the projector for a short period, use the blanking function rather than repeatedly turning the power on and off.
- Power off correctly: Wait until the fan stops before cutting power. Shutting down while hot causes sudden cooling, a common cause of lamp failure.
- Reset the lamp timer after replacement: Be sure to reset the lamp timer in the menu after installing a new lamp; otherwise, the machine will continue to alert based on the old runtime.
Related Search Links
- Zorsika Technical Support Center
- Projector Brand & Compatible Model Lookup
- Projector Lamp / Lens / Air Filter Product Library
Purchase Inquiry
For Christie 003-005160-01 solution inquiries, bulk pricing, or a complete model compatibility list, contact us through:
- Website: www.zorsika.com
- Phone: 020-38551187
- Email: sales@zorsika.com
- Business Hours: Monday to Friday, 9:00-18:00
Lamp module models, specifications, and model compatibility data in this article are sourced from the Zorsika product database. Data is continuously updated; actual quotes should be used for confirmation.