At a glance
- Specifications at a Glance
- Compatible Models: 9 Projectiondesign Projectors
- Why Choose Zorsika PRO for the Same Specifications
- FAQ
- Q: Why choose Zorsika PRO instead of the original?
- Q: How do I choose between original packaged, original bare, and replacement lamps?
- Q: What should I do if the projector shows "lamp not recognized" after replacement?
- Q: My projector is not on the 9-model list above. Can I use the 400-0600-00?
- Q: Is there an installation guide for the 400-0600-00?
- Three Things to Verify Before Purchasing
- Things to Keep in Mind After Replacing the Lamp
- Related Search Entries
- Purchase Inquiries
Projectiondesign 400-0600-00 projector lamp, UHP 220W/170W dual mode, reflector 45X45D, socket E19, compatible with 9 Projectiondesign projectors including F12, F30, F12 WUXGA, F12 1080p. Zorsika equivalent model 400-0600-00.


No need to read the manual: the core specifications of the Projectiondesign 400-0600-00 projector lamp, 9 compatible projector models, and the three things you should confirm before purchasing are all covered in this article.
Projectiondesign 400-0600-00 Projector LampSpecifications at a Glance
| Original lamp module model | 400-0600-00 |
| Zorsika equivalent model | 400-0600-00 |
| Compatible brand | Projectiondesign |
| Lamp module specification | UHP220/170W 1.0 E19 |
| Lamp type | UHP |
| Rated power | 220W (standard mode) / 170W (eco mode) |
| Arc gap | 1.0mm |
| Socket/base | E19 |
| Reflector size | 45X45D |
| Projection technology | DLP |
| Number of compatible models | 9 models |
The above specifications are sourced from the Zorsika product database. For the full technical datasheet, please contact our sales team.
Compatible Models: 9 Projectiondesign Projectors
The following are the verified compatible Projectiondesign projector models for the 400-0600-00, separated by commas:
F12, F30, F12 WUXGA, F12 1080p, F12 SXGA+, F10 AS3D, cineo12, F80 WUXGA, ACTION M25
Note: Projectors within the same generation often share the same lamp module. For models not listed, please contact Zorsika technical support for confirmation.
Why Choose Zorsika PRO for the Same Specifications
For high-volume, standard lamp modules like the 400-0600-00, the Zorsika PRO series offers an alternative with the same specifications as the original, with power, arc gap, and reflector size matched item by item against the original. Every unit is individually lit and tested before shipment, so it installs and works right away without any structural modifications.
- Specification matching: Power, arc gap, and reflector size are matched item by item to the original parameters
- Individual testing: Every lamp is lit and tested before shipment, ensuring brightness and stability
- Warranty commitment: 180-day warranty on the lamp; non-artificial damage under normal use is covered by after-sales service
- Stable supply: Supports bulk purchasing and project-based supply
In short: if you want original quality but with greater peace of mind overall, the Zorsika PRO series projector lamp is designed exactly for this scenario.
Note: Brightness and lifespan performance are significantly affected by projector condition, operating environment, and cooling conditions. Zorsika does not make uniform numerical promises, and we recommend testing 1-2 sample units before bulk purchasing.
FAQ
Q: Why choose Zorsika PRO instead of the original?
A: The core logic of the Zorsika PRO series lamp is "original parameters, self-managed quality control": power, arc gap, and reflector size are matched item by item to the original, but with an additional individual lit test before shipment and a 180-day warranty. Compared to the original, it offers greater peace of mind overall; compared to other alternatives, quality control is more consistent.
Q: How do I choose between original packaged, original bare, and replacement lamps?
A: If you prioritize brightness stability and long-term reliability, go with the Zorsika PRO series lamp first—it matches original parameters item by item, is individually lit and tested before shipment, delivers performance comparable to the original with greater peace of mind overall, and comes with a 180-day warranty. For regular commercial, educational, and conference room use, the PRO series is also the more reliable choice. While other replacement lamps are cheaper, the arc tube source and quality control vary widely, and the risk of brightness degradation and shorter lifespan is higher—these are only recommended for temporary backup units.
Q: What should I do if the projector shows "lamp not recognized" after replacement?
A: First, check whether the lamp hour counter has been reset—most alerts are caused by an uncleared timer. If the error persists after resetting, contact Zorsika technical support, and we will provide reset instructions and troubleshooting guidance for the corresponding model.
Q: My projector is not on the 9-model list above. Can I use the 400-0600-00?
A: The list covers verified models, but it is not exhaustive. Projectiondesign projectors within the same generation often share the same lamp module. Take a photo of the nameplate on the unit and the original lamp label and send it to Zorsika technical support, and we can help confirm compatibility.
Q: Is there an installation guide for the 400-0600-00?
A: Yes. The lamp door location and removal/installation steps are essentially the same across these Projectiondesign models. Contact Zorsika sales to get illustrated or video tutorials for the corresponding model.
Three Things to Verify Before Purchasing
- Check the nameplate model: Open the projector's lamp door, and the model on the lamp label should exactly match 400-0600-00. Some Projectiondesign models may have suffixes like -V, +, etc., but the lamp module is usually interchangeable. If in doubt, take a photo of the nameplate and send it to Zorsika technical support for confirmation.
- Confirm the lamp form: The same model comes in four forms—original packaged, original bare, replacement, and used—and they differ significantly. Original bare means an original arc tube with a third-party lamp housing, which typically offers the best overall value. Be sure to clearly specify which form you want on the order to avoid disputes upon delivery.
- Verify physical specifications: Reflector size 45X45D, socket E19, and arc gap must all match the original lamp. If any of these do not align, the lamp may not fit or may fail to light up.
Things to Keep in Mind After Replacing the Lamp
- Clean dust regularly: Dust buildup on the air intake and air filter directly raises the lamp's operating temperature. In dusty environments, clean every 1-2 months; in normal office environments, every 3-6 months.
- Make good use of eco mode: This lamp supports dual power modes of 220W / 170W. Switching to eco mode for everyday presentations can significantly reduce the thermal load on the lamp.
- Avoid frequent on/off cycling: Thermal cycling is one of the main sources of lamp wear. If the projector will not be used for a short period, use the shutter/blank function instead of repeatedly cutting power.
- Shut down properly: After turning off the projector, wait for the cooling fan to stop before disconnecting power. Cutting power while the lamp is still hot causes rapid cooling and is a common cause of lamp rupture.
- Reset the lamp hour counter after replacement: After installing a new lamp, be sure to reset the lamp hour counter in the menu; otherwise, the projector will continue to alert based on the old timer.
Related Search Entries
- Zorsika Technical Support Center
- Projector Brand and Compatible Model Lookup
- Projector Lamp / Lens / Air Filter Product Library
Purchase Inquiries
For consultation on the Projectiondesign 400-0600-00, bulk solutions, or a full list of compatible models, please contact us through the following channels:
- Website: www.zorsika.com
- Phone: 0086-20-38551187
- Email: sales@zorsika.com
- Business Hours: Monday to Friday, 9:00-18:00
The lamp module model, specifications, and compatible model data in this article are sourced from the Zorsika product database and are continuously updated. Please confirm with actual quotation inquiries.